To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 89 of 5197

IEC61850 - Support connection to servers requiring custom COTP parameters (network addressing)

The connector should be able to define all the COTP parameters to connect to IEC61850 servers.
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable GE Habconnect default attributes by query

Newest version of the GE HabConnect Connector supports default point attributes to be added at the field level. However, many attributes are set at the query level -- security for example. In addition, some installations potentially require dozen...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Support delayed startup of queries for GE HabConnect Connector

In some EMS configuration it is possible that to connect and query sampler before habitat database has initialized. This can cascade throughout PI -- analytics set to watch for minimum values, applications looking for status changes, etc. It is al...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

PI Connector for PCS 7 - Alarm & Events with same timestamp

The current version can't store alarms with same timestamp in the same PI Point. Unfortunately, this is the expected behavior of the Connector for PCS 7. This happens because of the mode the data is sent to the PI System (UPDATE mode which overrid...
gweissflog over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

IEC 60870-5-104: Interrogation Period

Currently, the PI Connector for IEC 60870-5-104's Interrogation Period (for each data source) can only go as low as 1 hour. As a PI System Administrator, I'd like to be able to set this value lower (on the order of seconds) so that all PI Points ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

AMI Interface: allow meter data to be writable to PI Point attributes

Synced to PI Square at https://pisquare.osisoft.com/ideas/29455 Currently, meter data can only be written to static attributes. Historizing the meter data may be useful if there are expected changes that should be monitored.
Guest over 3 years ago in PI Interfaces / General 0 Declined

Allow Buffer to communicate with other buffer

Currently the PI Buffer Subsystem only has the capability to speak directly with the Data Archive. This setup can have a negative impact on your Cyber Security setup as you are not able to leverage the DMZ between the IT/OT networks as it is desig...
Shaun Longworth over 3 years ago in PI Interfaces / General 0 Declined

Voir le statut de l'état multiples

garder la fonctionalité de processbook, lorsque l'on passe la sourie sur un objet qui est configuré en état multiple,ca serait de connaitre son statut et le nom du point
Guest almost 3 years ago in PI Interfaces / General 0 No status

Replace pipc.log and PI Message logs with the Event Viewer

PI Connectors already use the Event Viewer to log messages. It is time for PI Interfaces to do the same.
Kenneth Barber over 3 years ago in PI Interfaces / General 2 No status