To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 74 of 5194

Retire 32-bit versions of PI Interfaces that have a 64-bit version

These days, 32-bit operating systems are used for 1 of 2 reasons: Somebody accidentally installed the 32-bit version instead of the 64-bit version, which is a mistake that OSIsoft has no obligation to accommodate. The computer is very old, in whic...
Kenneth Barber over 3 years ago in PI Interfaces / General 1 No status

Migrate the PI Universal Interface (UniInt) Framework to use PI AF SDK

Most PI Interfaces are based on the PI Universal Interface (UniInt) Framework and rely on PI API and its successor, PI SDK. PI SDK has, in turn, been superseded by PI AF SDK. PI SDK also relies on the deprecated and insecure ActiveX technology, wh...
Kenneth Barber over 3 years ago in PI Interfaces / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI OPC Tools Upgraded for Packet Integrity Support

Please update the PI OPC Tools to support Packet Integrity authentication. The tools are useful and I would like to see them maintained and support with the latest requirements from Microsoft patches.
Kimlin Pen over 2 years ago in PI Interfaces / General 1 Future consideration

BUG: GE HABConnect with BitContainers

I have a case that was closed in 2017, where someone provided a workaround executable for the Interface that fixed the issue. I am assuming they were able to detect a bit container field if the MASK was set for the pitag, but unsure. However after...
Guest almost 3 years ago in PI Interfaces / General 0 No status

Remotely view logs

I understand that you can remotely view logs using pigetmsg. However this solution does not work for me as the interface is on a controlled network that only allows outbound traffic. I would like a way for the interface node to be able to push out...
Guest over 3 years ago in PI Interfaces / General 1 No status

Improved handling of PI Write failures

Provide a configuration option in UniInt interfaces, to enable shutdown of the interface if it consistently receives error messages when attempting to write to PI. Recently had an interface successfully connect to PI but not achieve write access t...
Guest over 3 years ago in PI Interfaces / General 0 No status

Allow scan class 0 to be monitored via Performance Counters

As a PI System Administrator, I would like to monitor the point count and other parameters for scan class 0 via Performance Counters. Currently, this is only exposed via the UniInt Health Tags.
Guest over 3 years ago in PI Interfaces / General 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Stay with RAD View

RAD view is easier to use for troubleshooting.