To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Ability to wait successful connection to PI Data Archive and download PI point information during startup

(Posted on behalf of our customer) It can reduce the chance of startup failure because of the connection to PI Data Archive time-out. It's also helpful if interface can reduce time to get PI point information from PI Data Archive.
Guest almost 4 years ago in PI Interfaces / General 0 No status

Monthly scans

Allow for monthly scan intervals for scan classes. i.e. "scan monthly on the first hour of the first day of every month".
Guest almost 4 years ago in PI Interfaces / General 3 No status

Allowing output point with source tag to keep working even after switching to secondary server

When primary server is down, secondary server is accessed instead of primary server, which is good. However, in the case of output point with source tag, it stops working, then restarting the interface instance of interest is needed. Of course, if...
Toshiro Chiba almost 4 years ago in PI Interfaces / General 0 No status

Retire 32-bit versions of PI Interfaces that have a 64-bit version

These days, 32-bit operating systems are used for 1 of 2 reasons: Somebody accidentally installed the 32-bit version instead of the 64-bit version, which is a mistake that AVEVA has no obligation to accommodate. The computer is very old, in wh...
Kenneth Barber almost 4 years ago in PI Interfaces / General 1 No status

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest almost 4 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Make the test reports actionable

Once the test runs and the report is generated, it is not easy to interpret potential failures that are included in the report and the only option is to contact techsupport. It is useful to make the report more actionable to know how to go about t...
Guest almost 4 years ago in Developer Resources / PI System Deployment Tests 0 No status

OMF: Container-level overrides

Ability to override Type-level property keywords on a Container level.
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 0 Planned

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Ability to monitor changes in interface configuration.

Need to know when the interface configuration was edited and which parameter was changed.
Mohammed Qasim Asghar almost 3 years ago in PI Interfaces / General 0 Declined

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status