Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

General

Showing 36

Customize UniInt Failover Sync File Permissions

Prior to UniInt v4.6.0.60, UFO sync files created during interface startup would inherit file permissions from their parent folder (assuming child inheritance had been enabled on the folder). With UniInt v4.6.0.60, this behavior changed and now s...
Guest over 1 year ago in PI Interfaces / General 1 No Status

Remotely view logs

I understand that you can remotely view logs using pigetmsg. However this solution does not work for me as the interface is on a controlled network that only allows outbound traffic. I would like a way for the interface node to be able to push out...
Guest over 1 year ago in PI Interfaces / General 1 No Status

Improved handling of PI Write failures

Provide a configuration option in UniInt interfaces, to enable shutdown of the interface if it consistently receives error messages when attempting to write to PI. Recently had an interface successfully connect to PI but not achieve write access t...
Guest over 1 year ago in PI Interfaces / General 0 No Status

Ability to wait successful connection to PI Data Archive and download PI point information during startup

(Posted on behalf of our customer) It can reduce the chance of startup failure because of the connection to PI Data Archive time-out. It's also helpful if interface can reduce time to get PI point information from PI Data Archive.
Guest over 1 year ago in PI Interfaces / General 0 No Status

Monthly scans

Allow for monthly scan intervals for scan classes. i.e. "scan monthly on the first hour of the first day of every month".
Guest over 1 year ago in PI Interfaces / General 3 No Status

Allow Buffer to communicate with other buffer

Currently the PI Buffer Subsystem only has the capability to speak directly with the Data Archive. This setup can have a negative impact on your Cyber Security setup as you are not able to leverage the DMZ between the IT/OT networks as it is desig...
Shaun Longworth over 1 year ago in PI Interfaces / General 0 Declined

Separate commonly used PI Interfaces that do not have a successor into read-only and write-only versions

Currently, it is recommended to use the read-only version of a PI Interface if only reading is required, and to have separate read and write instances of the read-write version of a PI Interface if writing is required. (Reference: https://docs.osi...
Kenneth Barber over 1 year ago in PI Interfaces / General 1 No Status

Device Status UniInt health tag should update during runtime without needing a status update

Currently, the device status is updated on startup, on change, on shutdown, and on each performance summary interval. However, for a device status tag created while the interface is running in a good state, the device status tag will remain at 'P...
Guest over 1 year ago in PI Interfaces / General 0 No Status

Upgrade the most commonly used PI Interfaces to use only the Microsoft Visual C++ 2015-2022 Redistributable

Please upgrade the most commonly used PI Interfaces so that the only Microsoft Visual C++ Redistributable version that they require is the 2015-2022 version. This will reduce the size of the install kit, make it faster to download, make it faster ...
Kenneth Barber over 1 year ago in PI Interfaces / General 1 No Status

Allowing output point with source tag to keep working even after switching to secondary server

When primary server is down, secondary server is accessed instead of primary server, which is good. However, in the case of output point with source tag, it stops working, then restarting the interface instance of interest is needed. Of course, if...
Toshiro Chiba over 1 year ago in PI Interfaces / General 0 No Status