To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 30 of 5192

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest over 3 years ago in Edge Data Store / Ingress 1 Declined

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Gabriel Verreault over 3 years ago in Edge Data Store / Installation 1 Future consideration

POINDexter app be modified such that addresses beyond 64000 can be used

POINDexter application be modified such that addresses beyond 64000 are able to be ‘tested’ / polled, rather than having to configure a tag to read those registers
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 No status

Don't change product version information response structure

The design of the /productinformation response has changed between EDS 2020 and EDS 2023 Patch 1. Our application missed the new position of the version string so I had to change code to catch it. I know the product has shipped so there is nothing...
Guest over 2 years ago in Edge Data Store / General 1 Declined

Interface for Modbus output to 4byte (32bit) registers

There are Modus supporting devices that feature 32bit single registers (e.g ROC800-Series). PI Interface for Modbus should be updated to have support to output to these 4byte (32bit) registers. Currently PI Interface for Modbus only has support f...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 2 No status

Swagger.json v0.3.1.0 CTP 2 shows errors in Swagger Editor

Swagger.json in EDS Version 0.3.1.0 CTP 2 produces semantic errors when trying to generate a client using Swagger editor
Guest over 3 years ago in Edge Data Store / General 0 Declined

Retrieve EDS Data Egress Status through REST API call

It would be great to have a REST API call available in EDS to get the current data egress state rather looking it up through the logfiles. The idea is to get information about when data was (successfully) egressed to OCS, AVEVA Data Hub or the PI ...
Guest over 3 years ago in Edge Data Store / Egress 1 Tell us more

Support Modbus device failover

Enhance the interface to support redundant Modbus devices with different network cards/IP addresses. The controllers would publish a status update on the active device, and the interface should request data from it accordingly.
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 Declined