Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 430 of 5219

Buffering Manager - add metrics for each buffered interface

When validating/troubleshooting data flow issues, it would be helpful to see metrics on which interfaces are actively sending data to the buffering subsystem via Buffering Manager. If an interface is in a bad state or stopped, it would be obvious ...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

EFGEN multi language support for event frame name

Hi, Existing EFGEN does not seem to support multi language (Double bytes characters) inputs for Event frame name. This result in the event frames names are being recorded in English char only. Would it be possible to implement the multi-langua...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 Declined

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks 11 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

User should be able to select multiple checkboxes in the backfilling / recalculation status. window.

Please refer the screenshot of existing window. There is no option to select multiple checkboxes. If user want to cancel multiple backfilling process which are queued (it was more than 50), then the cancellation option is not available to stop thi...
Guest almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analyzes are automatically switched off by the PI Analysis Service

In the case, that the PI AF Analysis Service is overloaded, there should be the possibility that faulty analyzes are automatically switched off by the PI Analysis Service. This ensures that all other analyzes functioning correctly. The failed anal...
Marcel Rieß almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

WIS support for TCP Response interface

If trusts are disabled in Data Archive, the TCP Response Interface will generate a logon error every time it performs a TCP request (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000032778). The interface should be updated, ...
mose almost 2 years ago in PI Interfaces / Other Interfaces 0 Evaluating

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status