To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 212 of 5213

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Stream-level debugging

As a PI System Administrator, I'd like to be able to trace values being received, and subsequently being sent by the Adapter, similar to PI Interfaces. Having the ability to trace/log timestamps and values for specific streams would greatly help ...
Guest over 3 years ago in AVEVA™ Adapters / General 0 Future consideration

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest over 3 years ago in AVEVA™ Adapters / General 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / General 0 No status

Support non-English Performance counter for PI PerfMon Interface

PI Interface for Performance Monitor can collect data from non-English Performance counters in version 1.x, but cannot in version 2.x. It would be good if version 2.x is also able to collect data from non-English Performance counters.
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

SNMP: Throttle scan specific informational messages as the interface may fill up logs every scan frequency

This is for SNMP version 1.6.3.0, the following message is printed every scan frequency: "Scan class for device will be skipped due to previous pending requests" And this needs to be throttled as the logs may be get filled up quickly with th...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

DNP3: store data as "bad"

Add functionality to treat the data as "bad" and send a digital state instead, when status flags are sent with the event and status bits are set to TRUE. Right now, the data is sent to PI and marked as "questionable". Note: This was previously En...
Clint Ramsey over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Allow PI APS to rename PI Points

PI APS is now not able to rename a PI Point name. If the item name is changed on the Datasource side we wish that APS rename the Pi Point.