Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 34 of 5194

Request for customizing the order of the interface instances in PI ICU interface list.

The interface instances` names contain the plants `names and I want to put the interfaces with the same plant name together in the list.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Source and destination tag mapping list

Customer would like the ability to have PItoPI create a list of tags that includes the FULL name of the source tags, as well as the destination tags they are mapped to.  This will greatly assist in managing tags that are being sent to a remot...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Make the ICU maximize button work.

Clicking the maximize button in the ICU makes it take up the whole screen but the fields remain the same size. If the fields resized as well, it would make reading and entry in some of the smaller fields easier.
rphilp1 over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 Declined

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC over 2 years ago in PI Interfaces / PI to PI Interface 1 Future consideration

Provide localized versions of PI ICU

For instance, cyrillic characters are not rendered correctly in spite of appropriate regional settings.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

PItoPI: Disabling Time adjustment

the ability to disable the timezone adjustment. currently we are calculating daily kpis on our global pi server. with PItoPI we are sharing it to the site pi-servers. so the daily kpi for e.g. 1st januar 2019 00:00AM sould alwas have that timesta...
MichaelHuber over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Follow PIMsgLog messages for the selected interface only

The Follow PI Message Log button on the ICU follows the entire PI Message Log. If there are lots of interfaces or other services running and posting to the message log, the messages for the interface I have just restarted get lost. It would be use...
AlistairTCO about 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Improve error messages in PI ICU

Currently if you attempt to create a service for a UniInt interface without a service ID you get an error message "Unknown Error" (see attached screenshot) Generally review and improve error messages to be meaningful but also allow the creation o...
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status