To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 22 of 5194

Request for customizing the order of the interface instances in PI ICU interface list.

The interface instances` names contain the plants `names and I want to put the interfaces with the same plant name together in the list.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Make the ICU maximize button work.

Clicking the maximize button in the ICU makes it take up the whole screen but the fields remain the same size. If the fields resized as well, it would make reading and entry in some of the smaller fields easier.
rphilp1 over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 Declined

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Provide localized versions of PI ICU

For instance, cyrillic characters are not rendered correctly in spite of appropriate regional settings.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Follow PIMsgLog messages for the selected interface only

The Follow PI Message Log button on the ICU follows the entire PI Message Log. If there are lots of interfaces or other services running and posting to the message log, the messages for the interface I have just restarted get lost. It would be use...
AlistairTCO about 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Improve error messages in PI ICU

Currently if you attempt to create a service for a UniInt interface without a service ID you get an error message "Unknown Error" (see attached screenshot) Generally review and improve error messages to be meaningful but also allow the creation o...
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status