Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 84 of 5194

Store an OPC Server's "VT_EMPTY" Data Type as a "Bad" in PI Data Archive

When there is a problem within an OPC Server, some Items receives "VT_EMPTY" data type values. PI OPC DA Interface ignores this information, and in PI Data Archive present to users and applications the last valid value - that might be incorrect.
jmalmeida 8 months ago in PI Interfaces / PI Interface for OPC DA 0 No status

Provide migration from PI BatchView

Provide a migration from PI Batchview displays in PI ProcessBook to PI Vision.
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 4 No status

PI Vision Event frames should show child elements in the Attributes panel of the Events comparison page.

When viewing event comparisons, the Attributes pane only lists the event frame attributes, the referenced element, and the referenced element's attributes. It currently cannot drill down and trend child element's attributes.
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Event Comparison: Add ability to set time range / end time (X-axis)

Sometimes there are very long event frames in the event comparison and it would be nice to be able to set the width of the x-axis to cut these event frames off at a certain duration. It's inconvenient to have to manually exclude them, and sometime...
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 3 No status

Support for the VT_UI4 data type

As a PI System User I would like to archive and analyse VT_UI4 data using the PI System.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Events Comparison: Configure via URL parameters

Allow configuring event comparison displays in an ad hoc way so that the search criteria and the attributes shown can be set through URL parameters. For example: As an operator, I would like to receive email notifications with hyperlink URL point...
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Allow multiple comparisons on one display

On BatchView we could place multiple comparisons on one display and have the current or running batch highlighted. This was great for a process with multiple batches running at different distinct phases on multiple units. A simple example would ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 1 No status

Enhance the OPC Interface to specify which groups are not receiving data

When a polled group does not receive data for more than 2 scan cycles, the interface updates the device status health point to 5 | Error | One or more groups not getting data. It will be useful to also specify which scan classes did not receive da...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Use check boxes to select which Events to Compare

As an end user, when going from related Events to the Compare Events page, I would like to see a check box which allows me to select which items to compare in the overlay trends.
Bethanne Robinson over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Enhancement for Advise tags to poll  OPC server when Excmax expires

Currently, when an advise tag does not get a value in an ExcMax period,  the interface will send the same value to PI over again without going to the OPC server (assuming that the OPC interface has not disconnected from the OPC server during ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status