To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 176 of 5194

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Tag Search dialog should have pointID as a default search criteria

As a PI System Administrator, I wish the Tag Search dialog made it easier to filter by pointID as I use this attribute commonly for management tasks and troubleshooting my PI System.  This could replace a less useful field such as Engineering...
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 Declined

Option to export PI Tags through SMT

No description provided
Guest over 3 years ago in AVEVA™ PI Server / System Management 3 Declined

Have PSD detect PI client tools installs

In our landscape, we usually create an ‘Admin’ server for each major PI system and install all the client tools on it for support staff to use for bulk work because it is normally easier (rather than their desktops) due to the admin servers being ...
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 Declined

Monitor OPC HDA interfaces

Needs OPC HDA interface support/monitoring in PI System Health.
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 Declined

Show usage of PI DA/AF in PSH

No description provided
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 Declined