Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Uninstall only the installed files & folders

It is standard for uninstallations to follow a procedure similar to this: Remove all files that were added during the installation. Then remove all folders that were added during the installation if they are currently empty. The PI Connector for ...
Kenneth Barber about 4 years ago in PI Connectors / PI Connector for UFL 1 No status

Payload configuration

I want to be able to define a POST or PUT payload in the connector. Also the option to import the payload through a file. Add a testing capability so you can see the respons from the POST or PUT command.
Hobbe about 4 years ago in PI Connectors / PI Connector for UFL 1 No status

PI UFL Connector - enable option to treat nulls values for fields as their defined data type instead of as strings

When the UFL connector sends a value that is null, it is treated as a string. As a result, any variables that are defined as other data types (other types as listed here https://docs.osisoft.com/bundle/pi-connector-for-ufl/page/field-section-state...
Paul Kim about 4 years ago in PI Connectors / PI Connector for UFL 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Rockwell CLX Connector

I am interested in a Rockwell CLX Connector.
Guest about 4 years ago in PI Connectors / New PI Connector Request 0 No status

Make a PI Signal Generator Connector (Ramp Soak + Random)

Please consider combining the PI Ramp Soak Simulator Interface and the PI Random Simulator Interface into a single PI Connector. The upgrade of these PI Interfaces is important because they come bundled with the PI Data Archive—nearly every PI sys...
Kenneth Barber about 4 years ago in PI Connectors / New PI Connector Request 1 No status

PI Connector for J1939/CAN

Connectivity to J1939/CAN based data sources; used for connectivity to operational and diagnostics data from commercial vehicles and heavy construction equipment.
Guest about 4 years ago in PI Connectors / New PI Connector Request 1 No status