To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

PItoPI should switch from COLD to WARM failover instead of exiting

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, older versions supported COLD failover. In the case of upgrading the interfaces, ...
Guest about 4 years ago in PI Interfaces / PI to PI Interface 2 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Support report generation against any batch level

As a RtReports user, I would like the context level I select in the RtReports Generator to be the context used in the generated report. For example, if I click on a PIUnitBatch I would expect to see only data from within the start and end time of ...
Guest about 4 years ago in AVEVA™ RtReports 0 Tell us more

Filter report search by status without specifying report name

While searching for reports in the RtReports Generator, using the 'Report Condition' filters requires specifying a report name. This is documented in the user guide under the section: Specify Batch Report Conditions It would be helpful to use the...
Guest about 4 years ago in AVEVA™ RtReports 1 Declined

Default batch search terms for all users when they log into the website

Default filter for all users every time they log into the application. The RtReports generator search page requires a user to enter the filter every time they log into the application. This is especially burdensome as the users are logged out afte...
Guest about 4 years ago in AVEVA™ RtReports 1 No status

pop-up to confirm the end of Approval cycle

It woul be useful to have a pop-up confirming that the approval cycle is properly completed.
Monica Rattaggi GSK over 2 years ago in AVEVA™ RtReports / Generator 0 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Be able to export data to excel with an option to enter/select time intervals

After creating a multidisplay, would it be possible to export the multidisplay data to excell spreadsheet with an option to choose time interval?
Guest 12 months ago in AVEVA™ RtReports / General 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status