To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 79 of 5199

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Bring back PIAttributeMaskToTag

Please, bring back the PIAttributeMaskToTag function. It disappeared after PI Datalink 2019SP1 Patch 1. Emulating it with a VBA function calling on an AF SDK COM wrapper is a lot of work and, most importantly, much slower that a native DataLink im...
Dorin IACOB about 3 years ago in AVEVA™ PI DataLink™ / Functions 4 No status

Allow for a timeshift of certain tags, depending on process time delay

To be able to delay some signals by x amount of hours would allow save tremendous amount of data handling into Excel. Some apps like Visplore offer that right at the display. I'm sure that the PI team can come up with a solution for that.
Guest over 1 year ago in AVEVA™ PI DataLink™ / Functions 0 No status

Allow converting compatible formulas to dynamic arrays on an entire spreadsheet

Right now, it is tedious to convert an existing spreadsheet to use dynamic arrays since each formula needs to be converted one-by-one. It would be helpful to have a way to convert formulas in bulk.
Jessica Rammo over 2 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

For compressed data, have the option to return the tagname (for example, similar to how the count is returned at the top).

If multiple tags are selected for 1 compressed data function, it is difficult to determine which data is associated with the tags. On behalf of Elizabeth Metzler elizabeth.metzler@enbridge.com
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Integrate with Excel Undo feature

If you make a mistake or overwrite information while working with PI Datalink information there is no way to undo it without deleting or recalculating the information completely.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status