To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 376 of 5219

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks 11 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

User should be able to select multiple checkboxes in the backfilling / recalculation status. window.

Please refer the screenshot of existing window. There is no option to select multiple checkboxes. If user want to cancel multiple backfilling process which are queued (it was more than 50), then the cancellation option is not available to stop thi...
Guest almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analyzes are automatically switched off by the PI Analysis Service

In the case, that the PI AF Analysis Service is overloaded, there should be the possibility that faulty analyzes are automatically switched off by the PI Analysis Service. This ensures that all other analyzes functioning correctly. The failed anal...
Marcel Rieß almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status