Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 63 of 5197

OMF sample in node-red

I would like a sample that shows creating OMF data in Node-RED
Guest over 3 years ago in Developer Resources / Sample Requests 0 No status

Split up installation and infrastructure of Deployment Samples

We have installed the OSI PI System without problem with the scripts provided in these samples. But now it's only possible to run the full script with the installation/configuration of the infrastructure included. Is it maybe possible to split up ...
Guest over 3 years ago in Developer Resources / PI System Deployment Samples 1 No status

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Make the test reports actionable

Once the test runs and the report is generated, it is not easy to interpret potential failures that are included in the report and the only option is to contact techsupport. It is useful to make the report more actionable to know how to go about t...
Guest over 3 years ago in Developer Resources / PI System Deployment Tests 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

OIDC Authentication

Could you add to the current list of supported authentication methods ("basic" & "kerberos") the OIDC authentication ? This was asked as an example by one of my customers.
Hervé Bajolle over 1 year ago in Developer Resources / PI Web API Samples 0 No status

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

UniInt Interface to support Kerberos when connecting to network drive for failover file

My ops team tells me that our UniInt-based interfaces (e.g. PItoPI, PerfMon, OPC DA) authenticate to network drives (when reading/writing failover files) using NTLM. I'm told Kerberos is much more secure than NTLM and they would like to see that b...
taterhead247 about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status