To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 158 of 5192

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

UniInt Interface to support Kerberos when connecting to network drive for failover file

My ops team tells me that our UniInt-based interfaces (e.g. PItoPI, PerfMon, OPC DA) authenticate to network drives (when reading/writing failover files) using NTLM. I'm told Kerberos is much more secure than NTLM and they would like to see that b...
taterhead247 about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Fix Bug for OPCInt_ReadWrite_2.7.2.20_.exe with Plug-in

I have high-frequency data need to collect,when i use OPC DA Plug-in TimeArray of OPCInt_ReadWrite_2.7.2.20_.exe ,it does not work.then i uninstall the opc interface 2.7.2.20 and install OPC DA 2.7.1.41,The Plug-in TimeArray work well.
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 2 Tell us more

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Device status tags do not show OPC DA server Invalid client handle errors

When OPC DA interface receives an "Server returned Invalid Client Handle" error, device status tags do not show that error and therefore potential situations where data is not being received by the interface are missed I would be good that device ...
asanzacedo almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status