Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1387 of 5194

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Supporting Decimal type for PI tag in PI Data Archive

For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li over 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove Microsoft Visual Studio 2010 Tools For Office Runtime (VSTO Runtime) from any install kits that contain PI AF Client

According to this, VSTO Runtime is included with PI AF Client for the sake of PI Builder. The installation of VSTO Runtime also causes the 32-bit and 64-bit versions of the Visual C++ 2010 Redistributable to be installed as well. However, accordin...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined

Add the option to set the Event Frame output to be the value of a string attribute with the longest time-span over the Event Frame Duration.

I have an Event Frame string attribute that changes its value over the duration of the Event Frame. I'd like to have the option to set the Event Frame output to be the value of the string attribute with the longest time-span over the Event Frame D...
Dave Tayler about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Tool to check if a PI Point is used in PI AF Analysis

I would like to suggest a tool (a native function or utility) to check whether there are calculations in PI AF that reference PI points. I should notice that is even for the situation that I don't know whether this PI point is an input or output o...
Gustavo Martins about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Add severity as a notification trigger criteria

Sometimes we have cases where we want to create the event but do not send a notification if the severity is low. I think it would be beneficial if we could add the severity as a criteria for notifications, that way we can choose at which point the...
Carlos Castro over 2 years ago in AVEVA™ PI Server / Notifications 0 No status

Ability to define if an analysis will be inherited from a base template.

I would like to easily define if a derived template will inherit an analysis. This derived template should have a check box on the analysis that says: 'Do not Inherent'. Without this option I have to disable the analyses mapped to the derived temp...
Alex Santos over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status