To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 67 of 5194

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Allow "PI View" target to be disabled

I would like the option to remove or disable the "PI View" target on the Data Warehouse, Azure, and SAP Hana editions.  In these editions, the PIIntegratorDB is expected to remain small because the data is published out to a separate databa...
Guest over 3 years ago in PI Integrators / General 1 No status

PI to Maximo integration

When PI is used to gather equipment sensor information but Maximo is used for asset management, it would be helpful to have a simple way to get equipment information out of PI and into Maximo.  This would be useful for scheduling preventative...
Guest over 3 years ago in PI Integrators / General 4 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Automatically add new attributes to existing views

As a PI administrator I want the integrator to detect new attributes on a template and add them to existing views automatically. This would be easier than creating a new view and asking users to reference this new output.
Guest over 3 years ago in PI Integrators / General 3 Declined

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more