To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 212 of 5288

Enable an integrity scan or compmax behavior for PI Connector for e-terrahabitat

The Connector only sends values that have changed. Not having the option to perform an integrity scan or functionality similar to compmax causes confusion to users looking at data in PI Vision. Some points can go for extended periods of time witho...
Allison Muraski over 3 years ago in PI Connectors / General 2 No status

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Option to split date and time into separate columns

SAP recommends using compression on column store databases to conserve RAM and disk space resources (https://blogs.sap.com/2016/08/12/how-and-why-to-do-compression-of-column-store-tables-in-sap-hana/). Since date+time values are typically unique a...
Guest over 3 years ago in PI Integrators / PI Integrator for SAP HANA 0 Declined

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Warning on PI Point Prefix value when adding a target PI Server

When creating a Destination PI Server on a Connector, it automatically gets assigned a default PI Point Prefix. Therefore if you delete and recreate a Destination PI Server, the Prefix will get reverted back to the default value. Please add a war...
Guest over 2 years ago in PI Connectors / General 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Reformat 2023 help/doc files so text not scrolling off the right hand side of page.

An example of the issue can be found in the 2023 Pi System Explorer help/user doc when searching for "Impact score". The text box goes past the edge of the page and you don't know if you are missing something important.
Steve Hampton over 2 years ago in AVEVA™ PI Server / Help / Documentation / Videos 0 No status