To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Support an analogue to the "step" PI Point attribute when creating PI Points

Even though it will indeed be useful to be able to specify whether data should be retrieved in a step-wise fashion, for new PI Points (assuming you're writing data to a PI Connector), it's important to be able to specify that those tags should hav...
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 1 In development

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 8 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 4 Tell us more

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 8 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 2 No status

The Adapter framework needs to be able to perform scaling on raw data

Many users want to use Adapters for the nre abilities they offer versus Interfaces: Support for containers, Linux, edge deployment, new failover and fault tolerance, integration with CONNECT Data Services, etc. HOWEVER, many sites use Interfaces t...
Daniel Lopez about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Future consideration

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Publish a sample of code to do an histogram

Publish a sample of code to do an histogram with PiVision extensibility. There is already a sample using a unique value (arrow) but there should be an exemple for charts to help people customise their experience further.
Guest almost 4 years ago in Developer Resources / Sample Requests 1 No status

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more