To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 200 of 5253

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 1 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Support derived templates

When replicating AF data to CONNECT, I would like to make sure that all assets configured from templates which are themselves based on derived templates, preserve the template inheritance. For instance, if I have a Mobile Equipment template, with ...
Max McKay about 1 year ago in PI to CONNECT / General 0 No status

The Adapter framework needs to be able to perform scaling on raw data

Many users want to use Adapters for the nre abilities they offer versus Interfaces: Support for containers, Linux, edge deployment, new failover and fault tolerance, integration with CONNECT Data Services, etc. HOWEVER, many sites use Interfaces t...
Daniel Lopez 7 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Future consideration

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Allison Muraski over 3 years ago in AVEVA™ Adapters / General 3 Tell us more

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status