To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 180 of 5259

Return Elements with Bad Values with AFSearch

As a programmer, I would like to search for and return elements with attributes that contain bad values  using the AFElementSearch Class in the AF SDK.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 1 Declined

Create a method to query a PIServer's licensed max tag count

No description provided
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 Declined

Search on multiple Categories in AFSearch

Several customers have asked for ability to search on multiple categories.  I understand from developers that a generic OR in AFSearch can be quite expensive, but allowing for search filter Category to support Equal or IN should not be expens...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 1 Declined

AF SDK Calls using the AFValues.GetValues should include an index of result events, this is to allow direct location of replacement events

The PIPoint.ReplaceValues method requires a replacement of every event in the timerange, however it also may reorder or miss events with the same time stamp. The issue is that if the client wants to replace only a certain event, but must find that...
Nathan Skitt over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 Declined

Have Status of an analysis

I would like to have status of analysis (Enabled, Disabled, Running, Error or Warning) via PI AF SDK with the attribute 'Status' or the method 'GetStatus'. In the library, we already have in AFStatus all the Status declared but not used. Thanks ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 1 Declined

Have an option for the PIPointList.RecordedValues Method to exclude the current value if now (*) is specified as the end time

With the PIPointList.RecordedValues Method, using an end time of * will include the current value. This is unexpected when the method "Returns a list of compressed values for the requested time range from PI."
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 2 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status