To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 340 of 5192

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Batch interface to AF connection health monitoring tag

Having a health tag for batch interfaces which monitors the connection status between the interface and its corresponding AF server. This way, users can be informed if there are any issues with the interface creating event frames on AF.
Guest about 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Ability to monitor changes in interface configuration.

Need to know when the interface configuration was edited and which parameter was changed.
Mohammed Qasim Asghar about 2 years ago in PI Interfaces / General 0 Declined

Allow PI OLEDB Enterprise client to specify which member of a PI Data Archive Collective to connect to.

Enable functionality for PI OLEDB Enterprise that will allow the client to specify which member of a PI Data Archive collective they wish to connect to. This functionality has already been enabled for PSE and would like something similar for PI OL...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 0 Declined

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Define more explicit system requirements for PI Interfaces

Define more explicit system requirements for PI Interfaces. According to a customer, despite the Buffer and Bandwidth Calculation Spreadsheet, currently available information does not allow for accurate hardware sizing.
Guest over 3 years ago in PI Interfaces / Installation 0 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Source and destination tag mapping list

Customer would like the ability to have PItoPI create a list of tags that includes the FULL name of the source tags, as well as the destination tags they are mapped to.  This will greatly assist in managing tags that are being sent to a remot...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

PI UFL Interface can read input files from non-UNC paths such as Azure File share

I would like the PI UFL Interface to be able to directly read from input files that are in non-UNC paths such as Azure File share, so I do not need to periodically copy the input files into another path.