To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 68 of 5194

Add element reference information to to RTQP tables.

In OLEDB Enterprise, we could find element references by type.  Currently, this information is not exposed in RTQP.  It would be helpful to be able to identify which type of reference an element is using.  One use case is for PI Adm...
Brent Bregenzer over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 Declined

Enable SSO on PI SQL client to connect and authenticate to PI SQL DAS(RTQP engine)

Currently PI SQL clients only support Kerberos & basic authentication. Enabling SSO on PI SQL client to connect and authenticate to PI SQL DAS(RTQP engine) would make PI data accessible from anywhere.
Sayan_Chowdhury over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Let PI SQL Client access SQL Tables

Let PI SQL Client access SQL Tables
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 Declined