Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 29 of 5192

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold almost 2 years ago in Edge Data Store / Historian 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest over 3 years ago in Edge Data Store / Ingress 1 Declined

Format based on Questionable attribute

Would like to be able to format any data value based on the questionable attribute. Use case: We have a report that uses 15 minute sampled data. The data is in a large table, one month displayed, date on the left hand side, time in 15 min incre...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Format 0 No status

Use Pattern Style "Solid" for PI Builder Retrieve cells that return Null values

For some monitors, the Pattern Style "50% Gray" causes the cell to have a shimmering effect.
Todd Jimeson almost 3 years ago in AVEVA™ PI DataLink™ / Format 0 No status

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Gabriel Verreault over 3 years ago in Edge Data Store / Installation 1 Future consideration

Don't change product version information response structure

The design of the /productinformation response has changed between EDS 2020 and EDS 2023 Patch 1. Our application missed the new position of the version string so I had to change code to catch it. I know the product has shipped so there is nothing...
Guest over 2 years ago in Edge Data Store / General 1 Declined

Swagger.json v0.3.1.0 CTP 2 shows errors in Swagger Editor

Swagger.json in EDS Version 0.3.1.0 CTP 2 produces semantic errors when trying to generate a client using Swagger editor
Guest over 3 years ago in Edge Data Store / General 0 Declined

Retrieve EDS Data Egress Status through REST API call

It would be great to have a REST API call available in EDS to get the current data egress state rather looking it up through the logfiles. The idea is to get information about when data was (successfully) egressed to OCS, AVEVA Data Hub or the PI ...
Guest over 3 years ago in Edge Data Store / Egress 1 Tell us more