To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Ability to control PI Vision time series symbols timerange based on attribute value

Possibility to control PI Vision time series symbols (trend/table) values based on attribute value formula for its time range duration.
Eduardo Miller 5 months ago in AVEVA™ PI Vision™ / Symbols 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Please provide the ability to rotate trends.

A trend is very useful but could be further improved if it was permitted to rotate these.
Guest 7 months ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 2 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add DATEADD and DATEDIFF functions to PI SQL Commander

When any time related functions need to be performed against timestamp columns in PI SQL Commander, one needs to utilize a significant amount of conversions to make this work. For example, if one needs to round timestamps to the nearest minute or ...
Guest almost 4 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 0 Declined

PI SQL Client to make use of the RecordedValue method and Retrieval Modes for the GetValue transposed function

When making use of the GetValue transposed function when creating a new Template specific Data Model, we can see that under the hood it makes us of the AF SDK call AFData.InterpolatedValue method to capture the data at a specified timestamp provid...
Guest almost 4 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status

Add Annotations support for RTQP Engine

I would like the RTQP Engine to be able to read annotations. My use case is the following : I have user that enter manual values into PI along with these values the operator will specify the reason for this manual input. The comment is stored in ...
cvallee almost 4 years ago in AVEVA™ PI System Access (PSA) / General 0 Declined

21 CFR Part 11 Electronic Signatures for manual data entry

Support 21 CFR Part 11 regulatory requirements for Electronic Signatures when manually entering data.
Guest almost 4 years ago in AVEVA™ PI Vision™ / Manual Data Entry 2 No status