Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 36 of 5197

UFL Designer should include a test mode to verify INI behavior with a data file.

One can do this, to some extent, piecemeal with functionality the UFL Designer already has. However, it's a very manual process and does not actually have a way to show what data would be sent to PI for a particular file. An explicit test mode or ...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

Add TCP option to PI UFL Interface

Currently the only two options are file reading or a serial interface. But what if you have ASCII data streaming from a TCP/telnet source? The configuration would be almost the same as serial - for the connection, rather than a serial port, just n...
John Alessio 7 months ago in PI Interfaces / PI Interface for UFL 0 No status

Rename "Compressed Data" to "Archived Data"

In the PI DataLink tab in the Ribbon, "Compressed Data" should be renamed to "Archived Data" since it actually retrieves archived data and not just compressed data. The icon should also be changed accordingly. Not all data in the PI Data Archive n...
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 0 No status

Option for PI Interface for UFL to purge read-only files

Create an option to allow the PI Interface for UFL to delete files with the read-only attribute.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

PI UFL Interface to extract data from csv files from multiple sub-folders within the main folder.

In case of csv files in subfolders within Main Path for UFl, PI UFL Interface should be able to search the csv files with placeholder and extract data from csv files from multiple sub-folders within the main folder.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

Rename "Timed Data" to "Data At Timestamps"

When I see "Timed Data", I think: "Well of course my data is timed! But what does this button do?". "Timed Data" retrieves interpolated/archived values at the given timestamps. Please rename "Timed Data" to better reflect this. I recommend "Data A...
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 0 No status

PI UFL Interface can read input files from non-UNC paths such as Azure File share

I would like the PI UFL Interface to be able to directly read from input files that are in non-UNC paths such as Azure File share, so I do not need to periodically copy the input files into another path.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

Manage interface names with service ID

As a PI system administrator, I would like to use the service ID to define the interface name so that I can organize and manage my interfaces more efficiently. I am currently able to do this with PItoPI but not UFL x64. Ideally, I would like to d...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 1 No status

Replace "https://techsupport.osisoft.com" in PI DataLink's About window

The link redirects to myOSIsoft. The link should be revised so that it does not redirect and possibly so that it leads to a different page instead. Either that or the link can be eliminated entirely.
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 3 No status

Rename "Time Filtered" to "Condition Time"

"Time Filtered" was meant to be interpreted as "Time [Spent] Filtered", but it can easily be misinterpreted as "Time[-]Filtered" (i.e. filtered by time, i.e. Compressed Data). Please rename "Time Filtered" to "Condition Time" so that the name bett...
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 0 No status