Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 728 of 5259

Don't run previous query when opening trend in PI System Explorer

When right-clicking and opening a trend or time series data, don't run the previous query. It can take too long. i.e. I loaded one year of data from a daily total tag (365 values). The next attribute I trend is a one-second tag (31 million values ...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined

Make AFDiag timeout based on AFService.exe.config settings

Make AFDiag timeout parameter based on AFService.exe.config settings instead of being hard coded.
Mohammed Al-Shaikh Jafar over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Customized PI System Explorer view

Currently PI System Explorer views lots of stuff that is not used by most users (ports, models etc.) also, there are some things that may depend on decisions of particular client - for example, I don't want my users to use Formulas. I suggest to p...
Czuprynski over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Include AFDiag /AddIdentity functionality to PSE

Adding an identity to an established large system can cause a flood of change records, leading to performance issues. The AFDiag /AddIdentity feature will bypass this issue, but it would be more convenient to have this functionality included in PSE.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Enhance connection logic to source PI server during Interface startup

When PitoPi Interface starts up, it prints a message saying that it secured a connection with the Target or Host PI server as follows:  PIAPI Successfully connected to :5450. Then it begins to load target PI points and it starts looking for t...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Add functionality to the interface to adjust timestamps by a configurable amount

This enhancement would add the ability to adjust timestamps to the PI to PI Interface (Beyond the included options for clock drift and subseconds). Potentially, a setting could be supplied to change the timestamps on all data transferred by a spec...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Please add a DAYOFWEEK function to the UFL interface

Can you please add a DAYOFWEEK function to the available functions in the UFL interface. This will greatly assist with the handling of daylight savings transitions (e.g. first sunday in April) as there is currently no easy way of determining the ...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

UFL Designer should include a test mode to verify INI behavior with a data file.

One can do this, to some extent, piecemeal with functionality the UFL Designer already has. However, it's a very manual process and does not actually have a way to show what data would be sent to PI for a particular file. An explicit test mode or ...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status