Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 135 of 5192

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Ability to log PI DataLink function usage

A centralized place to log PI DataLink usage, including the following information, The formula of the function Search requests made by PI DataLink The client/user information
Jeccie Qiu about 3 years ago in AVEVA™ PI DataLink™ / Settings 1 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Setting for Update Interval That Can Be Specified at the Excel Workbook Level

The customer would like to see an Update interval that can be specified at the Excel workbook level. The use case is that they run multiple Excel spreadsheets at the same time but need different update intervals for each. Workaround: use VBA to ac...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 0 Declined

Only include the worksheet in a formula if a sheet other than the one the formula resides is referenced

Copying formulas from one sheet to another is tedious because you must replace the sheet that Datalink forces in with the sheet you paste into even if all referenced cells are all on the same sheet. Please make the behavior similar to how Excel do...
Sublette-Sanofi over 3 years ago in AVEVA™ PI DataLink™ / Settings 0 No status

Restrict the "Root path" field on the "Current Value" menu to only display PI Data Archive servers previously connected to this machine.

We have 12 PI Data Archive Servers and another 12 PI AF Systems. I currently have to sort through a list of 124 "servers" when I setup to collect some PI data. Many of the 124 "servers" are old servers no longer in use or databases under PI AF Sys...
DavidMFairchild over 3 years ago in AVEVA™ PI DataLink™ / Settings 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status