To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 29 of 5194

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Presentation mode

An option to display fullscreen without the outer blue border.
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 No status

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Have ProcessBook and Coresight exhibit same behavior for imported ProcessBook Displays

In an imported ProcessBook display, I would like to see the same behavior in Coresight and in ProcessBook regarding changing the time context. In short, we want the value displayed to be based on the End Time of the display. We see this in Process...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 No status

add the option of remove processbook background when printing imported processbook display in pi vision

In Processbook, when we print the display, in file-->print we can choose if we check "print background" or not. But in vision, when we print the imported processbook display. We can only choose remove the pi vision background or not. Do not h...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Allow configuration of default AF identity ProcessBook displays are shared with

By default, PI ProcessBook displays in PI Coresight are shared with the AF identity "World". Allow the default identity PI ProcessBook displays are shared with to be configurable so that it can be set to one or more identities.
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 Declined