Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 61 of 5194

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Improve AF Transformer PostProcessing logging and performance

PostProcessing stage of the transformation (if using ParantID and ElementID) should use paging (or another approach) for a better performance, it should also be better logged and display number of objects processed, a number of objects in the list...
Guest over 3 years ago in AVEVA™ PI Server / General 0 Declined

Include a "Disable" option for Table Connections

Linked Tables can cause bad behaviors (freezes; attributes waiting for values) in PI System Explorer when the password supplied is no longer valid. The solution is to update the password, or delete the Table Connection if the new password isn't av...
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

Aveva Identity Manager Should have Buttons for all auth providers

Similar to many other sites that users are familiar with that have "Login with Google", "Login with Microsoft", etc buttons, AIM should provide buttons to make it clear as to what type of login the user should be using. Also, all of these buttons ...
Justin Crawford 6 months ago in AVEVA™ PI Server / General 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Allow specifying a path for orphaned elements for ParentID/ElementID functionality

Implement following logic for ParentID/ElementID functionality : if a parent element is not found  (invalid and/or empty ) - put a child element under specified hierarchy. there should be a separate configuration for both options: what to do ...
Guest over 3 years ago in AVEVA™ PI Server / General 0 Declined

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Pi Point removal tied to AF Element Delete

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/5268-pi-point-removal-tied-to-af-element-delete We need the ability to remove PI Points when deleting AF Elements in a single command execution like Builder does PI Point creati...
Guest over 3 years ago in AVEVA™ PI Server / General 1 No status