Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 116 of 5219

Make "Cancel" a button, not a link

In the configuration page of any data source, there is a "Save" button and a "Cancel" link. This is unnecessarily inconsistent. Please make "Cancel" a button.
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

Use units in the attribute templates of the element templates that PI Connectors create

Currently, all of the attribute templates of the element templates that PI Connectors create have their unit stated in their description but do not have a Default UOM assigned to them. Please assign Default UOMs to the attribute templates to save ...
Kenneth Barber over 3 years ago in PI Connectors / General 1 No status

Better error handling in DCM UI

For some cases where disallowed or poor configuration causes unexpected behavior, the UI should give a visual indicator and explanation.  Two examples: 1. No write access for Relay to AF DB when using the PSC.  Result: replication of AF ...
Brent Bregenzer over 3 years ago in PI Connectors / General 1 No status

OMF Support PI Connector Relay

Keep the OMF support in PI Connector Relay, also add the new OMF Versions to it not just only OMF 1.0. Not just leave the OMF support to the PI WebAPI. In many customer scenarios, the PI Connector relay is an easier solution than PI WebAPI.
Guest over 3 years ago in PI Connectors / General 0 Declined

Flexibility in configuring the DescriptionField tag (<DescriptionField value="TEXT"/>)

PI-Connector-for-GE-e-terrahabitat-1.1.1.42 Currently, the Connector for e-terrahabitat only allows the configuration of the Description Field to return only data from the TEXT field and PNTNAM table. The configuration of the Description field nee...
Guest 10 months ago in PI Connectors / Other specific PI Connector 0 No status

IEC61850 encryption

Implement TLS encryption between the IEC61850 Connector and the target IED(s) as per TS 62351.
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Discrimnate meta data changes of source items picked by PI Connector for IEC 60870-5-104

We would like to discrimnate when the meta data around the data item changes on the source. The digital states related to it, the description, etc. If these change, the connector will change them on our PI server. Currently PI Data Archive.does n...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Failover for e-terrahabitat

I would like to be able to configure two identical instances of the e-terrahabitat connector on different computers, only one of which collects data from habitat at any given time. In the event that the primary instance or the machine that hosts i...
Allison Muraski over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for MQTT - Support Backwards Compatibility

Need the ability for PI Connector for MQTT Sparkplug to support MQTT brokers/servers that are < v3.1.1, specifically v3.1
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

PI Connector for HART-IP: Remove UoM from being added to PI point "descriptor" attribute

Currently, the connector applies the UoM to the PI point "descriptor" attribute. If I want to write in a custom descriptor, every time I restart the connector, I then need to re-edit all of the points.
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status