Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest almost 4 years ago in PI Interfaces / Batch Interfaces 2 No status

Ability for PI Connectors to create future data point

Add the ability for PI Connectors to create future data point. This is especially useful for the PI Connector for UFL. The current workaround is to manually create the point as a StoredValues=FutureData.
Gabriel Verreault almost 4 years ago in PI Connectors / General 0 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Support Assigning Point Sources for Connectors

Connectors currently assign point sources; this is not user configurable.  In addition, all connector of like kind get the same point source.  This makes it difficult to determine which tags "belong" to which connector node.  Users ...
Brian Deslatte almost 4 years ago in PI Connectors / General 2 Declined

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest almost 4 years ago in PI Interfaces / Other Interfaces 2 No status

Support Warm Failover for the PI RDBMS interface

My Customer operates numerous RDBMS interfaces across their environment, some contain 1000's of output tags. With cold failover, the interface must register every output tag and establish all database connections which can take several minutes for...
Janelle Minich 5 months ago in PI Interfaces / PI Interface for RDBMS 1 No status

Enhance the OPC DA interface to avoid mixing polled and advise tags on the same scan class

The interface does not log any informational messages about polled and advise tags getting mixed up on a scan class. Currently it would detect that polled tags are part of scan class 1 and reject it and print the following: E 13-Apr-16 17:26:18 ...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Connector for IEC 60870-5-104 : being able to subscribe to a predefined set of IEC addresses

Currently based on the PI Connector for IEC 60870-5-104 user guide [Introduction to PI Connector for IEC 60870-5-104 ] The connector creates the corresponding PI points for each Information Object Address (IOA) associated with an ASDU and a Group....
Guest about 2 months ago in PI Connectors / General 0 No status

PI Connector Relay support write modes

While writing data to PI through the connector relay there seems to be no option to control the write mode . E.g."[-109] Value at This Time Already Exists" is shown in the logs if the archive already contains an event with the same timestamp. The ...
Guest almost 4 years ago in PI Connectors / General 2 No status