To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 133 of 5194

Display's Start/End Time in Vision Calculation

be able to have a Vision calc utilize the current start and end time of the display
Matt Voll over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Multistate does not recognize value in calculation (Text)

Allow multistate to recognize text
Guest 4 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Transformations and scaling

Add the ability to configure PI points so that the PI Connector for OPC UA performs transformations and scaling on the values before being archived.
Jose Sanchez Colunga over 3 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar about 1 month ago in PI Connectors / PI Connector for OPC UA 0 No status

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Use a calculation in another calculation

Currently, you cannot use a calculated variable in another calculation on PI Vision. This complicates calculations because all operations must be done under one calculation.
Navern Moodley over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

OPC UA: allow a host name override

Allow a hostname override when connecting to the OPC UA endpoint.   We have some use cases where the URL returned by two independent OPC UA servers has the same name.  This prevents the Connector from connecting to the correct endpo...
Clint Ramsey over 3 years ago in PI Connectors / PI Connector for OPC UA 6 Declined

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 3 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,