To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 114 of 5194

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Description

The OPC UA connector automatically creates tag descriptions when new tags are loaded (tag only mode). This behaviour may not always be desired . In our example we want to change the descriptions to something more meaningful. It would be useful to...
tdeibe01 over 3 years ago in PI Connectors / PI Connector for OPC UA 1 Evaluating

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Import function for data selection in PI Data Data Collection Manager

During setup of a new data source we always face a long list of several thousand tags where we only need a couple of hundred. We have also a list with tagnames available as .xlsx or similar. The idea is to have an import function for that list to ...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

AutoPointSync for OPC DA should work on 64bit servers.

AutoPointSync for OPC DA does not install or run correctly on 64bit servers. As most new servers are 64bit this would seem to be an essential capability.
zubzub over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

change the default behavior of the OPC DA interface to use /DC

per the OPC DA 2.x spec, the OPC server will call us back for all points that have a changes; even those points where we are polling. We have a switch to disable the callbacks for points that are not set to advise: /DC Can we make that the defau...
Clint Ramsey over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI OPCtoCSV Tool: Subbranch filter depth

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch however it recurses all sub-subbranches. We have an OPC server with around 20k items that we read into ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.
ValterFostini over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

A progress bar during data discovery

It would be great to have some indication of how far the Connector is through the data discovery process.
David Scott over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status