To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 102 of 5194

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Enable setting tag attributes in the PI Connector for OPC UA (gen1 and gen2)

The PI Connector for OPC UA (gen1 and gen2) should have ways to set tag attributes. There should be way to automatically set the PI point attributes like point and data security.
Paul Kim about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow Publishing of a Narrow Data Format

It would be helpful to be able to publish to a narrow format to reduce downstream impact due to the fact that we don't have to change the table structures when the assets change. (flexibility) https://en.wikipedia.org/wiki/Wide_and_narrow_data
Guest over 3 years ago in PI Integrators / General 1 No status

Add Time Offset Option to OPC UA Connector

Please add a time offset option to the OPC UA Connector, similar to the old OPC DA interface (see attached screenshot). In come cases the OPC UA server may not actually be sending timestamps that are in UTC (ex. in local time) so an offset is nee...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

An import-export feature for PI Connector for OPC UA similar to the one used to configure OPC DA points

Having to select the OPC UA server points to import from a list with thousands of points where a naming rule is not followed is a never-ending task using the OPC UA Connector web interface. My suggestion is to create an interface similar to the on...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Add a checkbox disabling Tag and Element creation

Case1: OPC UA Connector configured in a way that if the automation system will offer new tags, they will be created on PI system automatically. However, this makes running out of tags on the PI Server. Is there a possibility to start the OPC UA Co...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Allow English PI Time to be used regardless of integrator language settings

Other products (such as DataLink) will allow for English PI Time to be utilized regardless of the language settings. For instance, both "*-8h" and "*-8horas" will work in DataLink if Spanish is the selected language. However, only "*-8horas" will ...
Guest over 3 years ago in PI Integrators / General 0 Declined

Create Start Menu shortcut for Integrator

It would be nice if the PI Integrator installation created a Start Menu shortcut to the Integrator User Interface, similar to how a PI Connector installation creates a Start Menu shortcut linked to the PI Connector Administration page.
Guest over 3 years ago in PI Integrators / General 0 Declined

Integrator should have a status page

The Integrator application server should have a status page ("OK" or "Running") so that clients or load balancers can easily determine whether the site is up or not.  This should be implemented when the Integrator eventually supports high ava...
Guest over 3 years ago in PI Integrators / General 0 Declined