Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 110 of 5199

Make the PI Connector for OPC UA support the use of the "Reverse Connect Client Facet"

In the reverse connect methodology - The server opens the socket and calls the client with a Reverse "Hello" message. After that, the client will use the already open channel (which initially fails with establishing the handshake) and call the nor...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 3 No status

Add the feature to create writing tags via OPC UA

In the OPC DA adapter, we are able to write values if we create a PI Point with a specific Point Source (that is prepared to receive values) and if we configure the source tag properly. This kind of feature is not available in OPC UA, and it would...
Lucas Mazutti 7 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Enable setting tag attributes in the PI Connector for OPC UA (gen1 and gen2)

The PI Connector for OPC UA (gen1 and gen2) should have ways to set tag attributes. There should be way to automatically set the PI point attributes like point and data security.
Paul Kim over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow to change Connection Default Preference for all AF SDK applications

If the user wants his custom applications running on a particular client machine to connect to the secondary server of a collective, he could of course hard-code that. But that becomes impractical if there are a lot of custom programs or they are ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 No status

Export method for AFLibrary class

As an AF SDK developer, I would like to be able to export AF Server Libraries (https://docs.osisoft.com/bundle/af-sdk/page/html/T_OSIsoft_AF_AFLibrary.htm) to .xml files or strings in order to easily share them with other AF Servers. An example o...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 3 No status

PI System Explorer - The TAG Search option should display the tree path of the located element.

This would allow for quicker localization of the element where the tag is located, facilitating the modification of the configuration, as well as performing analysis recalculations and time series data visualization.
Guest over 1 year ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 No status

af sdk PIPointQuery should allow multiple use of filter name per AND condition, so ranges can be searched

Currently the PIPointQuery cannot contain a filter condition with same filter name twice per AND condition of the query string. PointId:>5 AND PointId:<10. This would cause an error. Therefore filtering for a certain range is annoying as ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 Declined

Provide ability to specify ID (Guid) when creating elements or attributes

Provide ability to specify ID (Guid) when creating elements or attributes in AF via the AF SDK. When replicating data from an external system to AF, we need to be able to use the same GUID that has already been established.  This will allow...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 16 No status