To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 104 of 5198

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins almost 2 years ago in AVEVA™ Adapters / General 2 Already exists

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 5 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 2 No status

Allow options to alter the way the connector handles different qualities (bad, questionable)

At this time, the connector does not expose any way to alter the way data of different qualities (bad, good, questionable) is handled. The PI OPC Interface allows several different options with regards to “quality” such as "send only GOOD quality ...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 1 Declined

Connector should rescan UA server, on a configureable basis, for new objects already defined in CSV file

It would be helpful if the UA Connector could rescan the UA server for new objects that have already been selected in the AvailableTypeDefinitions file and add them to the server on a configurable frequency.  We primarily use the UA Connector...
Steve Hampton over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 2 years ago in AVEVA™ Adapters / General 5 Future consideration

Ability to monitor which OPC UA Connector is active in a failover pair

As a PI administrator, I need to monitor which OPC UA Connector in a failover pair is currently active. When the primary OPC UA Connector goes down, I need an email notification, and vice versa when the secondary OPC UA Connector goes down.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

OPC UA - Add Option to not browse item before creating a monitored item

Need an option in Tag only Mode to force connector to create a monitored item without browsing item. Some OPC servers require creating a monitored item BEFORE the item can be browsed.
JTWhite over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Allison Muraski over 3 years ago in AVEVA™ Adapters / General 3 Tell us more

Warm and cold PI Connector for OPC UA failover

Currently only hot failover is featured for the PI Connector for OPC UA but this creates a lot of strain on the data sources. We need to be able to select warm/cold failover mechanism.