Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 104 of 5199

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 0 No status

Add Digital Set in OPC UA

Possibility to specify the digital set of a digital tag (CLOSE/OPEN)
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make the PI Connector for OPC UA support the use of the "Reverse Connect Client Facet"

In the reverse connect methodology - The server opens the socket and calls the client with a Reverse "Hello" message. After that, the client will use the already open channel (which initially fails with establishing the handshake) and call the nor...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 3 No status

Stream-level debugging

As a PI System Administrator, I'd like to be able to trace values being received, and subsequently being sent by the Adapter, similar to PI Interfaces. Having the ability to trace/log timestamps and values for specific streams would greatly help ...
Guest over 3 years ago in AVEVA™ Adapters / General 0 Future consideration

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest over 3 years ago in AVEVA™ Adapters / General 0 No status

Add the feature to create writing tags via OPC UA

In the OPC DA adapter, we are able to write values if we create a PI Point with a specific Point Source (that is prepared to receive values) and if we configure the source tag properly. This kind of feature is not available in OPC UA, and it would...
Lucas Mazutti 7 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / General 0 No status

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Enable setting tag attributes in the PI Connector for OPC UA (gen1 and gen2)

The PI Connector for OPC UA (gen1 and gen2) should have ways to set tag attributes. There should be way to automatically set the PI point attributes like point and data security.
Paul Kim over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status