Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 193 of 5193

Get data by polling

Support acquiring data by polling the OPC UA server rather than subscription.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

Manual Data Entry Function May Be Useful with Macros Becoming Antiquated

Manual entry data function may be useful with macros becoming antiquated. Support for making annotations may be useful enhancement as well. Note: This was previously Enhancement 19290OSI8.
Somchai Limwongsaree over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 Declined

Setting to allow the omission of error strings in Calculated or Filtered Results

Give the customers either an option or an application setting that allow them to omit error strings from function output. This would allow them to more easily chart results. Some examples of current strings that cause charting problems include, th...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 1 No status

Support for UOM conversions

Being able to specify a UOM that is not the default UOM and having the value returned converted in all functions Note: This was previously Enhancement 25182OSI8
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 2 No status

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar 27 days ago in PI Connectors / PI Connector for OPC UA 0 No status

Extend PI Data Archive time zone setting support

Currently PI DataLink allows you to select the PI Data Archive time zone setting however this setting only applies to data items or expressions that contain either a PI point or a PI AF attribute that is a PI point data reference. If the data item...
Guest 6 months ago in AVEVA™ PI DataLink™ / Settings 0 No status

Auto-Update enabled by default on Excel startup

Add a setting to turn on the "Auto-Update" button on Excel startup automatically. Note: This was previously Enhancement 26678OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 1 No status

Transformations and scaling

Add the ability to configure PI points so that the PI Connector for OPC UA performs transformations and scaling on the values before being archived.
Jose Sanchez Colunga over 3 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

Time Zone Specification to Represent Data in

Letting the customer specify the time zone in which to represent the data would be a nice enhancement. Note: This was previously Enhancement 2729OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 10 No status

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status