Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Redfish - Allow port selection from the DCM UI

When configuring the PI Connector for Redfish, it will default to port 443 for the target Redfish Server. Servers are commonly installed on custom ports. Currently, the port needs to be manually edited in in DataSource.config.json.
Gabriel Verreault almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

WITSML - XML in debug logs instead

To troubleshoot data collection issues in the PI Connector for WITSML, it is often required to trace the request made by the connector and responses (XML) returned by the WITSML Server. This is currently only available when running the connector i...
Gabriel Verreault almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

Use DESCRIP_POINT, ANALOG for e-terraPipeline description strings

The PI Connector for e-terraHabitat HabConnect SAMPLER pulls tag descriptions from the PNTNAM and ALGNAM records. For Oil & Gas e-terraPipeline (a.k.a. ETPL or "LMS") customers, the DESCRIP field on those records are usually left blank, or the...
KPRoth almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

IEC61850 - Support connection to servers requiring custom COTP parameters (network addressing)

The connector should be able to define all the COTP parameters to connect to IEC61850 servers.
Gabriel Verreault almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable GE Habconnect default attributes by query

Newest version of the GE HabConnect Connector supports default point attributes to be added at the field level. However, many attributes are set at the query level -- security for example. In addition, some installations potentially require dozen...
Guest almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

Support delayed startup of queries for GE HabConnect Connector

In some EMS configuration it is possible that to connect and query sampler before habitat database has initialized. This can cascade throughout PI -- analytics set to watch for minimum values, applications looking for status changes, etc. It is al...
Guest almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

PI Connector for PCS 7 - Alarm & Events with same timestamp

The current version can't store alarms with same timestamp in the same PI Point. Unfortunately, this is the expected behavior of the Connector for PCS 7. This happens because of the mode the data is sent to the PI System (UPDATE mode which overrid...
gweissflog almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status

IEC 60870-5-104: Interrogation Period

Currently, the PI Connector for IEC 60870-5-104's Interrogation Period (for each data source) can only go as low as 1 hour. As a PI System Administrator, I'd like to be able to set this value lower (on the order of seconds) so that all PI Points ...
Guest almost 4 years ago in PI Connectors / Other specific PI Connector 1 No status

Install and configure a Connector at a site with few IT resources

As an admin, I need to install and configure a Connector or application that collects, buffers, and transmits data to CONNECT data services so that I can start making displays that help me monitor my process.
Guest about 4 years ago in PI to CONNECT 0 No status

Handling Replaced or Redeployed Devices

The ability for data generating devices in the field to be redeployed to new assets and have the data in OCS reflect this reality. Scenarios: * Device 123 is capturing data from Asset A and redeployed to Asset B at this timestamp. * Device 456...
Guest about 4 years ago in PI to CONNECT 0 No status