To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 3 Tell us more

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
sahilp 12 months ago in AVEVA™ Adapters / General 1 No status

Add a parameter for the Adapter to increase the Keep-Alive wait time

Currently, there is no parameter on the Adapter side to increase the Keep-Alive wait time. It would be best to add parameter for the Adapter to increase the Keep-Alive wait time.
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...
Nick Ciampa 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Have more KPIs/diagnostics for PI System Connector

In Data Collection Manager, it would be good to have a status on Currently Synchronized Elements, Events, Tags, structure. Be able to count the events and tags that failed to synchronize since some time. Missing values in tags between source and d...
Guest almost 4 years ago in PI Connectors / PI System Connector 1 Tell us more

Install and configure more than one PI System Connector instance per server

At local industrial sites, we deploy use cases different in nature and end user consumption in separated AF DBs, like OEE, PSM, Autoclave, utilities, etc. We need to centralize these individually into our central PI System. We need to segregate th...
Christian Leroux over 3 years ago in PI Connectors / PI System Connector 0 No status