To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 116 of 5194

UFL Connector NoReplace fuction ( Store Mode)

What we would like is a third option with UPDATE and INSERT, which prevents a new value for the same timestamp from being processed. Such as a NO REPLACE mode.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 2 No status

Delete mode in Wonderware InBatch interface

When run in delete mode for WWInBatch interface, it uses the data source as the system of record--any open batch in SQL will be deleted. However, as abandoned or done  batches are open in WonderWare but closed in PI, the interface may delete ...
Willy Seah Wei Liat over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Double check window required when deleting an instance in PI Event Frames Interface Manager

As a PI System Admin, I would like to see a confirmation window (acceptation pop-up message), when deleting Interface instances in PI Event Frames Interface Manager. This would minimize the deletion of the instances by error.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Enhance Visibility of Event Frame Generator/Batch Interface History Recovery Status

Currently when running any event frame generator interface (EFGen, PIFTBatch, etc.) in history recovery mode, there is no way to monitor progress of the actual history recovery. The only way to determine status is to check message logs periodicall...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Factory Talk Batch Interface EVT file contains useful data in the Recipe column. Can we please add Recipe as a placeholder in the Interface?

The EVT file from FTB has 27 columns, the most populated one is Recipe. There is useful information there that could be used to filter and select data for storage in PI. Unfortunately it isn't available in the Placeholder list of 42 placeholders f...
Nathan Skitt 9 months ago in PI Interfaces / Batch Interfaces 2 Tell us more

Enable logging of 5.x batch interface messages to the local PI message log again

Message logs for 5.X Batch interfaces and Connectors are written to Windows Event Viewer instead of PI Message Logs as in previous versions. The Windows Event Log is extremely slow compared to viewing PI message logs, the filtering is worse, the m...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 2 Declined

Add possibility to Configure purge time/output path/REST channel authentication in the admin/ui webpage without GlobalConfig.ps1

It's more complex and not the safest way to change the PurgeTime and OutputPath parameters with GlobalConfig.ps1 by specifing password in command line. It would be better if this option would be availble for UFL admin on the admin/ui webinterface....
Yuriy Sadovskiy over 1 year ago in PI Connectors / PI Connector for UFL 0 No status

Add a type casting function or operator

The INI files would be shorter and more readable if the PI Connector for UFL had a type casting function or operator. For example, if you are incrementing a Counter variable (type Int32) for each data line, and your tag names are Tag1, Tag2, etc....
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Make a version of SkipFile() that stops processing the current file immediately

The current SkipFile() function tells the PI Connector for UFL to skip the remaining lines in the file, but the PI Connector for UFL will continue to execute the rest of the code in the "per message" section that the current line triggered. Pleas...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

UFL Connector - sort input files by parameters other than name

Allow the UFL Connector to sort input files by parameters other than the name.  This will be useful in cases where file naming conventions will lead to large amounts of OOO data.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 No status