To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 99 of 5194

UFL Connector - sort input files by parameters other than name

Allow the UFL Connector to sort input files by parameters other than the name.  This will be useful in cases where file naming conventions will lead to large amounts of OOO data.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Uninstall only the installed files & folders

It is standard for uninstallations to follow a procedure similar to this: Remove all files that were added during the installation. Then remove all folders that were added during the installation if they are currently empty. The PI Connector for ...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Payload configuration

I want to be able to define a POST or PUT payload in the connector. Also the option to import the payload through a file. Add a testing capability so you can see the respons from the POST or PUT command.
Hobbe over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Separated output folder for different data source

I am interested to be able to configure for each data source separately output folder where processed data files are stored. Currently, all processed data files are moved to one OUTPUT folder and afterwards zipped. I would like to have this functi...
Guest almost 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Use the most recently used Locale as the default

The default Locale is currently "English - United States" for all new data sources. Please consider using "English - United States" as the default Locale only for the 1st data source, and using the most recently used Locale as the default for all ...