To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 354 of 5222

Trend - configure scales - multiple scales, ability to define min max for each data item

configure scales - multiple scales, ability to define min max for each data item
John_Gardner over 3 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 1 No status

Ability to import displays from other applications like Wonderware of iFIX to PI Vision Displays

No description provided
Guest over 3 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 1 No status

PI Vision Display Utility - Allow Multiple AF or Data Archive Mappings during Display Import

Right now, it is only possible to import a display with one AF or Data Archive server remapping. I would like the option to import a display that has multiple AF Servers in the source and remap each of them to new destination servers.
Guest over 3 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 No status

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Connector for Wonderware to be able to detect dll files in other drives other than C drive

Had a customer that just installed PI Connector for wonderware of current version (v1.6.9.14) and his connector is unable to start. Upon discussion after troubleshooting, it was noted that the directory where dll files can be located on customer's...
Chaur Ann Poh over 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold over 2 years ago in Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Quicker Graphic Editing -- Double Left Click in Design Mode to bring up "Format" Sidebar Or Format Multiple Same-type assets at same time

It feels extremely cumbersome and time consuming to start building a graphic from scratch and it feels that way because we have to manually right click then select "Format" on each individual asset to start changing them. For example, adding a set...
Guest over 2 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 No status