Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 29 of 5194

Wonderware Historian Connector Should store description in an AF attribute

Wonderware Historian Connector should store description in an AF attribute. It has the description in hand as it is written to the PI tag descriptor
Brian Deslatte over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Alert user when the interface discards values

Example:  When using a distribution tag, the number of tags returned and number of values sent to PI can be mismatched, due to missing aliases or data that does not need to be collected. It would be helpful to identify what values are droppe...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

The PI Connector for Wonderware Historian should automatically delete tags that no longer exist in the Wonderware Historian

As a PI System Admin, I would like the PI Connector for Wonderware Historian to automatically delete PI Tags that no longer exist in the Wonderware Historian to ensure that the two systems are in sync.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

PI Connector for Wonderware to be able to detect dll files in other drives other than C drive

Had a customer that just installed PI Connector for wonderware of current version (v1.6.9.14) and his connector is unable to start. Upon discussion after troubleshooting, it was noted that the directory where dll files can be located on customer's...
Chaur Ann Poh about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Wonderware Historian Connector - Allow Custom Tag Naming

The Wonderware/AVEVA Historian has some different illegal characters than PI tags and there are also cases where a single tag prefix isn't sufficient (e.g. when storing data from multiple buildings in the WW Historian). The Connector should have t...
Sublette-Sanofi over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect
AlexMeade almost 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Disable Meta data collection for the PI Connector for Wonderware Historian

We would like to have a way to disable the PI Connector for Wonderware Historian's ability to  collect descriptions and engineering units in the historian.  These can be incorrect at times in the Wonderware Historian.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

PI Connector for Cygnet - Historical Data Recovery

The PI Connector for Cygnet is normally used for real-time data acquisition. But, some times it becomes necessary to migrate large volumes of historical data between Cygnet and PI. There is a back filling application that can be used to do this, ...
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Add option to select interface behavior for bad timestamps (PI RDBMS)

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the interface attempts to use the current timestamp instead and logs the following error: "pitm_settime() error - 15002. Using current...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status