Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 26 of 5194

Upgrade the PI Interface Configuration Utility to a responsive web-based user interface

OSIsoft's migration from PI Interfaces to PI Connectors is very slow. Even after the migration is complete, many PI Interfaces will not be upgraded to PI Connectors, so users will continue to use the PI Interfaces and the PI ICU to configure them....
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Allow PI-ICU to Create/Edit Stored Credentials in Credential Manager

An issue we run into often is that most of the accounts that are used to run our interfaces (mostly OPC DA) are different from accounts we use to configure the interfaces. Because these interfaces run on different domains, we have to store an acco...
Brian Rock over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 4 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Tombayu Hidayat about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Upgrade the PI Interface Configuration Utility to use only the Microsoft Visual C++ 2015-2022 Redistributable

The PI Interface Configuration Utility install kit currently includes both the 2012 and the 2019 Microsoft Visual C++ Redistributables. Please upgrade the PI Interface Configuration Utility so that it requires only the Microsoft Visual C++ 2015-20...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No status

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

Enhance the PI-ICU to include a rolling buffer regardless of connection to the PI Data Archive

During a Disaster Recovery test our team discovered that there will be up to 24 hours of data loss since our VM's are cloned once a day and the PI-ICU interfaces don't start caching data until the data archive has been disconnected. Essentially - ...
Guest almost 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Request for customizing the order of the interface instances in PI ICU interface list.

The interface instances` names contain the plants `names and I want to put the interfaces with the same plant name together in the list.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status