To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 62 of 5194

The PI Connector for WITSML should be able to perform history recovery and real-time data collection at the same time

As a PI System Administrator, I would like to configure the data collection mode for the PI Connector for WITSML for each data source so that I can perform history recovery and real-time data collection without having to host multiple installation...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

PI Connector for GE eTerraHabitat

As a GE eTerraHabitat user, I would like to have a nice way to choose which tags I want to create on the PI System, without having to force them through the Approved Changes folder on the installation directory of the Connector. It would be better...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

Flexibility in configuring the DescriptionField tag (<DescriptionField value="TEXT"/>)

PI-Connector-for-GE-e-terrahabitat-1.1.1.42 Currently, the Connector for e-terrahabitat only allows the configuration of the Description Field to return only data from the TEXT field and PNTNAM table. The configuration of the Description field nee...
Guest 9 months ago in PI Connectors / Other specific PI Connector 0 No status

IEC61850 encryption

Implement TLS encryption between the IEC61850 Connector and the target IED(s) as per TS 62351.
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Discrimnate meta data changes of source items picked by PI Connector for IEC 60870-5-104

We would like to discrimnate when the meta data around the data item changes on the source. The digital states related to it, the description, etc. If these change, the connector will change them on our PI server. Currently PI Data Archive.does n...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Failover for e-terrahabitat

I would like to be able to configure two identical instances of the e-terrahabitat connector on different computers, only one of which collects data from habitat at any given time. In the event that the primary instance or the machine that hosts i...
Allison Muraski over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for MQTT - Support Backwards Compatibility

Need the ability for PI Connector for MQTT Sparkplug to support MQTT brokers/servers that are < v3.1.1, specifically v3.1
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

PI Connector for HART-IP: Remove UoM from being added to PI point "descriptor" attribute

Currently, the connector applies the UoM to the PI point "descriptor" attribute. If I want to write in a custom descriptor, every time I restart the connector, I then need to re-edit all of the points.