To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 102 of 5194

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow different naming for Parent and Child Event Frames

Allow a different naming pattern for the child event frames. End result would have the long, uniquely named EFs in the Parent EF as usual, but the Child EFs could have a simplified name, like the level of an alarm that is pulled from an attribute ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 7 No status

late notification

At times I have event frames that generate late for various reasons that trigger a notification. Since it was late we have no need to get the notification. I would like a way to not have a notification trigger if it is late.
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 Tell us more

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Allow selection of output timestamp for values written by the outputs at close feature in Event Frames

It would be nice to have the option to select either starttime or endtime of the eventframe as the timestamp for the value that will be written a PI tag using the Outputs at close feature in Event Frames. Currently, it will only write the value wi...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 5 No status

Custom Severity Levels for Event Frames (EF) Triggers

Enable the ability for end-user to manage custom severity levels for event frames, to allow for better communications across response teams and business unit functions. Exposing EF severity levels within a PI Notifications messages is very helpfu...
jtepfer@ebay.com over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Event Frame (EF) Linking

Ability to link Event Frames coming in from different sources (batch & mes interfaces, EFgen, PI Analytics, custom, etc.) together based on rules and monitoring an EF attribute SO THAT it's easier to associate time frame context and data that ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Aggregate event frames to a time series

As an user, I want to be able to treat event frame like time series data, such as number of active event frames, sum of an attribute, so that I can continuously monitor the evolution of event frames over time.